Xuzhou Huiya Imp&Exp Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Liu Jenny
  • Company Name : Xuzhou Huiya Imp&Exp Co., Ltd.
  • Tel : 0086-516-83998180
  • Fax : 86-516-83998180
  • Address : Jiangsu,XuZhou,Room 4-4034 Building45,EastHuanghe Road
  • Country/Region : China
  • Zip : 221005

Syringe Driver Model BD-5000

Syringe Driver Model BD-5000
Product Detailed
Related Categories:Medical Consumables
1. Simple and safe operation. 2. Three kinds of injection modes 3. Adding language select function

Model: BD-5000  Syringe pump characteristics (enhanced type)

Technique itemTechnique specifications:  
Maximum injection rate:1500ml/h (different syringe has different maximum flow rate)
Applicable syringe: Automatic identification of 5ml, 10ml, 20ml, 30ml and 50ml.
Drug name: such drugs as Penicillin and vancomycin can be shown; more drugs can be set according to the demand.
Power supply:AC100-240V, 50/60HZ
Maximum weight:  <3.0kg
Battery:    Rechargeable lithium polymer battery 7.4V, 1600mA Working for 4 hours (25ml/h) after fully being charged
Max power consumption: 25VA
Accumulated volume display:0.1~999.9
Injection accuracy:  ±3%( after being adjusted, up to ±2%)
Rate increment: 0.1ml/h
Preset injection volume setting:0.1ml~9999.9ml
Preset time setting:    0-33h20 minutes
Classification: class Ⅱ BF type             
Injection rate range:   5ml: 0.1ml/h---100ml/h    10ml: 0.1ml/h---200ml/h 20ml: 0.1ml/h---400ml/h        30ml: 0.1ml/h---600ml/h    50ml: 0.1ml/h---1500ml/h
Bolus rate: 5ml:100ml/h  10ml:200ml/h  20ml:400ml/h  30ml:400-600ml/h  50ml:400-1500ml/h
Alarm:     over, injection near completion, no AC power supply, CPU communications error, pump stuck,   disengaged.
Selectable modes:1. Rate mode   2.  time mode   3. Body weight mode
Time mode: Volume limit: 0.1-999.9ml  time: 1-2000min
Body weight mode: Body weight: 0.1~300kg   drug limit: 0.1~999.9mg   volume limit: 0.1~999.9ml  Dose: 0.1~9999.9 (subject to unit, dosage, liquid, weight and syringe) unit: mg/kg/h, ug/kg/min
OCCUL value: 0.04Mpa-0.16Mpa, pressure change and the current phase against block valve position of syringe can be shown.
KVO rate:  Adjustable range: 0.1ml/h-5.0ml/h, choose “OFF” to cancel KVO function if no need KVO (entering into KVO after OCCUL when running)
Electromagnetic compatibility:Meet the requirements of IEC60601-1-2(2001 version)
Electrical safety: Meet the requirements of IEC60601-1:1995, GB9706.1-2007

Syringe Driver Model BD-5000

Other products


Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.