Syringe Driver Model BD-5000
Product Detailed
Related Categories:Medical Consumables
1. Simple and safe operation.
2. Three kinds of injection modes
3. Adding language select function
Model: BD-5000 Syringe pump characteristics (enhanced type)
Technique item | Technique specifications: |
Maximum injection rate: | 1500ml/h (different syringe has different maximum flow rate) |
Applicable syringe: | Automatic identification of 5ml, 10ml, 20ml, 30ml and 50ml. |
Drug name: | such drugs as Penicillin and vancomycin can be shown; more drugs can be set according to the demand. |
Power supply: | AC100-240V, 50/60HZ |
Maximum weight: | <3.0kg |
Battery: | Rechargeable lithium polymer battery 7.4V, 1600mA Working for 4 hours (25ml/h) after fully being charged |
Max power consumption: | 25VA |
Accumulated volume display: | 0.1~999.9 |
Injection accuracy: | ±3%( after being adjusted, up to ±2%) |
Rate increment: | 0.1ml/h |
Preset injection volume setting: | 0.1ml~9999.9ml |
Preset time setting: | 0-33h20 minutes |
Classification: | class Ⅱ BF type |
Injection rate range: | 5ml: 0.1ml/h---100ml/h 10ml: 0.1ml/h---200ml/h 20ml: 0.1ml/h---400ml/h 30ml: 0.1ml/h---600ml/h 50ml: 0.1ml/h---1500ml/h |
Bolus rate: | 5ml:100ml/h 10ml:200ml/h 20ml:400ml/h 30ml:400-600ml/h 50ml:400-1500ml/h |
Alarm: | over, injection near completion, no AC power supply, CPU communications error, pump stuck, disengaged. |
Selectable modes: | 1. Rate mode 2. time mode 3. Body weight mode |
Time mode: | Volume limit: 0.1-999.9ml time: 1-2000min |
Body weight mode: | Body weight: 0.1~300kg drug limit: 0.1~999.9mg volume limit: 0.1~999.9ml Dose: 0.1~9999.9 (subject to unit, dosage, liquid, weight and syringe) unit: mg/kg/h, ug/kg/min |
OCCUL value: | 0.04Mpa-0.16Mpa, pressure change and the current phase against block valve position of syringe can be shown. |
KVO rate: | Adjustable range: 0.1ml/h-5.0ml/h, choose “OFF” to cancel KVO function if no need KVO (entering into KVO after OCCUL when running) |
Electromagnetic compatibility: | Meet the requirements of IEC60601-1-2(2001 version) |
Electrical safety: | Meet the requirements of IEC60601-1:1995, GB9706.1-2007 |